Status:

UNKNOWN

Comparison of DCT, ORA and GAT in Eyes After Penetrating Keratoplasty

Lead Sponsor:

Sheba Medical Center

Conditions:

Corneal Transplantation

Eligibility:

All Genders

18-90 years

Brief Summary

To compare intraocular pressure (IOP) measured by the Reichert Ocular Response Analyzer (ORA), Pascal dynamic contour tonometer (DCT) and Goldmann applanation tonometer (GAT) in eyes after Penetrating...

Detailed Description

A few tonometers are used today in clinical practice for measuring intra ocular pressure (IOP). Each tonometer is based on different technology. Post penetrating keratoplasty (PK) eyes are at risk fo...

Eligibility Criteria

Inclusion

  • Eyes after KPL surgery at the Goldschleger Eye Institute in the last 10 years.

Exclusion

  • Uncooperative subjects for whom good quality results are unattainable.

Key Trial Info

Start Date :

May 1 2009

Trial Type :

OBSERVATIONAL

Allocation :

ESTIMATED

End Date :

May 1 2010

Estimated Enrollment :

35 Patients enrolled

Trial Details

Trial ID

NCT00834782

Start Date

May 1 2009

End Date

May 1 2010

Last Update

September 15 2009

Active Locations (2)

Enter a location and click search to find clinical trials sorted by distance.

Page 1 of 1 (2 locations)

1

Goldschleger eye institute, Sheba medical center

Ramat Gan, Israel

2

The Goldschleger eye institute, Sheba Medical Center, Tel Aviv University

Ramat Gan, Israel