Status:

ACTIVE_NOT_RECRUITING

Visceral Manifold and Unitary Device Study for the Repair of Thoracoabdominal Aortic Aneurysms

Lead Sponsor:

Sanford Health

Collaborating Sponsors:

Dakota Vascular

Conditions:

Thoracoabdominal Aneurysms

Eligibility:

All Genders

18+ years

Phase:

NA

Brief Summary

The primary objective of the Visceral Manifold and Unitary Device Study is to assess the use of the thoracic bifurcation and the visceral manifold or the unitary device to repair thoracoabdominal aort...

Detailed Description

The primary objective of the clinical investigation Visceral Manifold and Unitary Device Study is to assess the use of the thoracic bifurcation and the visceral manifold or the unitary stent graft sys...

Eligibility Criteria

Inclusion

  • An aneurysm with a maximum diameter of ≥ 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements
  • Aneurysm with a history of growth ≥ 0.5 cm in 6 months
  • Saccular aneurysm deemed at significant risk for rupture
  • Symptomatic aneurysm greater than or equal to 4.5 cm
  • Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit
  • Proximal landing zone for the thoracic bifurcation stent graft:
  • •≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA)
  • Diameter in the range of 26-42 mm
  • Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold
  • Proximal landing zone for the unitary manifold stent graft:
  • Nonaneurysmal aortic segment including previously placed graft material (neck) with a minimum seal zone length of 3 cm
  • Diameter in the range of 19-32 mm
  • Iliac artery or aortic distal fixation site greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm
  • Age: ≥ 18 years old
  • Life expectancy: \> 1 year

Exclusion

  • General exclusion
  • Patient is a good candidate for and elects for open surgical repair
  • Can be treated in accordance with the instructions for use with a legally marketed
  • Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site
  • Unwilling to comply with the follow-up schedule
  • Inability or refusal to give informed consent
  • Urgent or emergent presentation
  • Patient is pregnant or breastfeeding
  • Patient has a contained rupture
  • Patient has a ruptured aneurysm
  • Patient has a dissection in the portion of the aorta intended to be treated
  • Obstructive stenting of any or all of the visceral vessels
  • Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
  • Medical exclusion criteria
  • Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel:Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE)
  • Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed
  • Uncorrectable coagulopathy
  • Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment
  • Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair
  • Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina)
  • Systemic or local infection that may increase the risk of endovascular graft infection
  • Baseline creatinine greater than 2.0 mg/dL
  • History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome)
  • Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material
  • Anatomical exclusion criteria
  • Minimum branch vessel diameter less than 5 mm
  • Thrombus or excessive calcification within the neck of the aneurysm
  • Anatomy that would not allow maintenance of at least one patent hypogastric artery
  • Anatomy that would not allow primary or assisted patency of the left subclavian artery
  • Expanded Selection Arm Inclusion Criteria
  • Patient that meets the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm:
  • Minimum branch vessel diameter less than 5 mm
  • Urgent or emergent presentation
  • Patient has a contained rupture
  • Patient has a ruptured aneurysm
  • Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated
  • Poor performance status including two major system failures (cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular)
  • Baseline creatinine greater than or equal to 2.0 mg/dL
  • Anatomy that would not allow for maintenance of at least one hypogastric artery
  • Anatomy that would not allow for primary or assisted patency of the left subclavian artery
  • Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in the a landing zone that expands beyond any limits of the previously placed graft material
  • Obstructive stenting of any or all of the visceral vessels
  • OR
  • Patient that meets criteria for inclusion in the primary study arm and:
  • Would not be eligible for the primary study arm per a documented reason other than those outlined above, and
  • Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.

Key Trial Info

Start Date :

February 1 2015

Trial Type :

INTERVENTIONAL

Allocation :

ESTIMATED

End Date :

December 1 2029

Estimated Enrollment :

250 Patients enrolled

Trial Details

Trial ID

NCT02294435

Start Date

February 1 2015

End Date

December 1 2029

Last Update

December 16 2024

Active Locations (1)

Enter a location and click search to find clinical trials sorted by distance.

Page 1 of 1 (1 locations)

1

Sioux Falls, South Dakota, United States, 57117

Visceral Manifold and Unitary Device Study for the Repair of Thoracoabdominal Aortic Aneurysms | DecenTrialz