Actively Recruiting
Anteroposterior Versus Anterolateral Electrode Position for Electrical Cardioversion of Atrial Fibrillation
Led by McMaster University · Updated on 2025-05-14
1500
Participants Needed
2
Research Sites
227 weeks
Total Duration
On this page
AI-Summary
What this Trial Is About
Atrial fibrillation is the most common heart rhythm disorder (arrhythmia) worldwide. Nearly 40 million people are affected by atrial fibrillation worldwide, and this number is expected to increase by over 50% by 2050. Atrial fibrillation can cause strokes, heart attacks, heart failure, poor quality of life and even death. Almost half a million deaths worldwide are expected to be related to atrial fibrillation by 2050, and many billions of dollars are spent on atrial fibrillation related healthcare in North America every year. We believe health outcomes for patients with atrial fibrillation, and healthcare costs associated with treating atrial fibrillation could be improved by optimizing existing treatments for atrial fibrillation and maximizing the likelihood of restoring normal heart rhythm. This allows them to benefit from lower stroke risk, better heart function, fewer symptoms and increased quality of life. Restoring normal sinus rhythm earlier prevents atrial fibrillation from causing permanent structural damage to the heart that in turn, makes atrial fibrillation intractable. Furthermore, patients in whom initial attempts to control atrial fibrillation are unsuccessful frequently require more medications or invasive catheter ablation procedures which are costly and carry substantial risk. Electrical cardioversion is the main way physicians restore normal heart rhythm. In this procedure, the heart is "shocked" back into normal rhythm using two electrodes on the chest. Done correctly, this procedure is safe and effective. Many things are known about electrical cardioversion, for example, the best type and amount of electricity to use. What we don't know is the best position of the electrodes on the chest and whether applying direct, physical pressure to the electrodes makes cardioversion more successful. Our prior research suggests that improving positioning and applying pressure may improve cardioversion, but this finding needs to be verified with a rigorous, dedicated trial. This study will demonstrate whether front-to-back, or front-to-side placement of the electrodes is more effective for electrical cardioversion of atrial fibrillation. We will also demonstrate whether manually applying pressure to the electrodes makes cardioversion more effective. Should our trial demonstrate a benefit for these techniques, we expect them to be universally applied around the world. Because hundreds of thousands of cardioversions are done each year, even small increases in cardioversion success means thousands fewer patients progress to needing more medications or invasive procedures to manage their atrial fibrillation. We will study consenting adults presenting for non-urgent cardioversion of their atrial fibrillation. After explaining the study to participants and gaining their consent, we will randomly assign them to front-to-side or front-to-back electrode placement. Patients who remain in atrial fibrillation after the first shock will randomly receive either manual pressure or not. We will compare the success of cardioversion for front-side versus front-back electrode placement, and for manual pressure versus none. We will evaluate success by using electrocardiograms to assess for restoration of the heart rhythm back to normal. We hypothesize that anterolateral electrode positioning is superior to anteroposterior electrode positioning. We also hypothesize that manual pressure is effective relative to none, when applied in patients who have had one unsuccessful shock already.
CONDITIONS
Official Title
Anteroposterior Versus Anterolateral Electrode Position for Electrical Cardioversion of Atrial Fibrillation
Who Can Participate
Eligibility Criteria
You may qualify if you...
- Consenting adult patients scheduled for non-emergent electrical cardioversion of Atrial Fibrillation or Flutter
You will not qualify if you...
- Insufficiently anticoagulated for cardioversion as per Canadian Cardiovascular Society guidelines or have not undergone trans-esophageal echocardiography to rule out left atrial thrombus
- Anatomic contraindication to anterolateral or anteroposterior electrode placement such as skin conditions or wounds
AI-Screening
AI-Powered Screening
Complete this quick 3-step screening to check your eligibility
Trial Site Locations
Total: 2 locations
1
Hamilton Health Sciences
Hamilton, Ontario, Canada, L8L2X2
Actively Recruiting
2
St Joseph's Healthcare Hamilton
Hamilton, Ontario, Canada, L8N4A6
Actively Recruiting
Research Team
W
William McIntyre, MD
CONTACT
How is the study designed?
Study Type
INTERVENTIONAL
Masking
NONE
Allocation
RANDOMIZED
Model
PARALLEL
Primary Purpose
TREATMENT
Number of Arms
2
Not the Right Trial for You?
Explore thousands of other clinical trials that might be a better match.
Sign up to get personalized trial recommendations delivered to your inbox.
Already have an account? Log in here