+1 877 705 1914• 24 / 7
HIPAA Compliant
ISO 27001 Certified

Actively Recruiting

Phase Not Applicable
Age: 35Years - 70Years
All Genders
ID07778199

Evaluating Passive Fit of Full-Arch Mandibular Implant Frameworks Using Digital IO-Connect and Reverse Scan Body Techniques Versus Conventional Impressions

Led by Mansoura University · Updated on 2026-08-21

8

Participants Needed

1

Research Sites

13 weeks

Total Duration

AI-Summary

What This Trial Is About

Researchers are evaluating the passive fit of complete-arch mandibular implant-supported frameworks made using three different impression techniques in patients who are completely edentulous and receiving four implants in the lower jaw. The study compares a non-calibrated splinted digital scan body system called IO-Connect, a Reverse Scan Body digital impression method, and a conventional splinted open-tray impression technique. The goal is to determine which method provides the best fit to avoid mechanical and biological problems. Participants will undergo all three impression techniques in a randomized crossover design. Each technique involves fabricating an implant-supported framework Group I uses digital impressions with IO-Connect splinted scan bodies, Group II uses the Reverse Scan Body digital technique with extraoral scanning and superimposition, and Group III uses a conventional splinted open-tray impression with polyvinyl siloxane and dental stone casts. Each framework will be clinically evaluated for passive fit using the Sheffield one-screw test and radiographically with intraoral periapical radiographs taken using a parallel technique. During the study, participants will have frameworks tried in and tested 3 months after implant placement for each impression method. Assessments include clinical fit testing and radiographic evaluation to check for microgaps at the implant-framework interface. The study involves eight patients, with evaluations occurring at specific timepoints after implant placement to compare the three techniques. The entire participation covers the period from implant placement to framework try-in and evaluation.

CONDITIONS

Brief Title

Passive Fit of Implant-Supported Frameworks: Digital vs Conventional Impressions

Research Team

A

Ahmed H Hazem Elsayed Helmi Atwa, BDS

Not the Right Trial for You?

Explore thousands of other clinical trials that might be a better match.
Sign up to get personalized trial recommendations delivered to your inbox.

Already have an account? Log in here