Bradycardia means a slower-than-usual heart rate, while heart block occurs when electrical signals are delayed or interrupted as they travel through the heart. A slow rate can be normal during sleep or in trained athletes, but some rhythm problems ca...
Search Bar & Filters
Found 80 Actively Recruiting clinical trials
Actively Recruiting
Researchers are evaluating two different pacing methods for patients with slow heart rates, called bradycardia. This study compares the common right ventricular pacing approach with a newer physiological pacing method that includes His bundle and left bundle area pacing. The trial aims to better understand how these pacing techniques affect patient outcomes, including mortality and heart failure morbidity, in a large group of 2600 patients. Participants will receive a pacemaker implant and be randomly assigned to either right ventricular pacing or physiological pacing. The physiological pacing may involve His bundle pacing or left bundle pacing, but if these are not successful, biventricular pacing will be used. A subgroup of 500 participants will take part in an optional echocardiographic sub-study to assess heart function changes over a 24-month period. Throughout the study, patients will be assessed at baseline and every six months after randomization, with follow-up lasting up to 78 months. Researchers will monitor outcomes such as mortality, heart failure events, device-related safety issues, patient quality of life, symptoms, and pacemaker-derived data like arrhythmias and activity levels. The echocardiographic sub-study will measure specific heart function changes to understand pacing-induced cardiomyopathy. Participants involvement includes implantation, regular follow-up visits, questionnaires, and optional imaging assessments.
Actively Recruiting
Researchers are investigating the effects of cardiac resynchronization therapy CRT in patients with symptomatic heart failure who have a low left ventricular ejection fraction LVEF of 35% or less and left bundle branch block LBBB. About one-third of patients receiving CRT do not show improvement, and this study aims to understand how CRT affects coronary blood flow in the left anterior descending artery LAD in patients with non-ischemic dilated cardiomyopathy and LBBB. The study hypothesizes that CRT improves heart function not only by resynchronizing the hearts contractions but also by enhancing blood flow in coronary arteries. The study will enroll 60 patients with heart failure caused by non-ischemic dilated cardiomyopathy and LBBB, some with CRT devices and some without. Researchers will measure absolute coronary flow and resistance in the LAD using invasive procedures, including fractional flow reserve FFR, with CRT devices turned on and off to compare effects. These measurements will help evaluate how CRT influences blood flow and heart muscle work. Participants will undergo invasive flow measurements during the study procedure to assess coronary blood flow and heart function. Researchers will closely monitor absolute coronary flow during the procedure to understand the impact of CRT. The study is conducted at an outpatient cardiology clinic and involves assessing heart rhythm, medical therapy stability, and other heart health factors. The total duration and follow-up details are not specified, but the focus is on real-time measurements during the procedure.
Actively Recruiting
Researchers are investigating the benefits of combining left ventricular lead pacing with Left Bundle Branch Area Pacing LBBAP using a cardiac resynchronization therapy defibrillator CRT-D in patients with heart failure who have a left bundle branch block LBBB. This study compares this combined approach, called Left Bundle Branch Optimized Cardiac Resynchronization Therapy LOT-CRT, to LBBAP alone. The trial is designed as a randomized 2x2 crossover feasibility study focusing on echocardiographic changes as primary and secondary outcomes, with additional assessments including NT-proBNP levels and patient-reported quality of life. Participants receive either LBBAP therapy or LOT-CRT for six months each in a randomized sequence. The CRT-D device is programmed accordingly, with the left ventricular lead turned off for LBBAP alone and on for LOT-CRT. An additional observational treatment arm includes patients who could not be randomized due to unsuccessful device implantation, allowing real-world data collection. During the study, participants undergo evaluations of heart function through echocardiographic measures like left ventricular ejection fraction and end-systolic volume at baseline, six months, and twelve months. Exploratory assessments include blood biomarker NT-proBNP and quality of life questionnaires. The study involves close monitoring and follow-up visits over a total of 12 months to assess treatment effects and safety.
Actively Recruiting
Researchers are studying pre-term infants who experience apnea and bradycardia to explore a new device that may predict and reduce these episodes before they occur. This trial aims to assess the accuracy and effectiveness of an algorithm using a closed-loop vibro-tactile stimulator in managing these conditions during two separate 4-hour periods. Participants will undergo a randomized crossover trial where they experience two 4-hour sessions one with the vibro-tactile stimulation activated when apnea or bradycardia episodes are predicted or detected, and one without any stimulation. The device connects additional ECG leads to monitor heart activity, providing data to trigger the stimulation or remain inactive depending on the session. During the study, infants will be continuously monitored for heart rate and oxygen levels using the device and other assessments. Researchers will measure occurrences of bradycardia and hypoxemia during both intervention periods to evaluate the devices performance. The study lasts for these two 4-hour periods on separate occasions, with close monitoring throughout to ensure safety and data collection.
Actively Recruiting
This research aims to evaluate complications and long-term health outcomes of the single-chamber Aveir Atrial Leadless Pacemaker device, also known as the Aveir AR LP system. The study focuses on Medicare patients with cardiac pacemakers, including those with arrhythmia and bradycardia, to better understand device performance and patient survival over time. The study uses real-world evidence by merging multiple datasets from Abbott and the Center for Medicare Services. It includes Medicare patients implanted with the Aveir AR Leadless Pacemaker or a single-chamber atrial transvenous pacemaker from any manufacturer. No additional device interventions are required, as the study collects and analyzes existing data from these patients. Participants are observed through ongoing data collection without direct study visits or procedures. Researchers will assess acute device-related complications within 30 days and survival rates at two years, along with chronic complications at six months and device re-intervention rates over two years. The study includes a waiver for informed consent due to its observational nature and uses continuous Medicare claims data to monitor outcomes up to 2031.
Actively Recruiting
This research aims to evaluate the long-term safety of the Aveir dual-chamber leadless pacemaker in patients with cardiac pacemakers, arrhythmia, or bradycardia. It is an observational post-approval study designed to provide safety data by using real-world evidence methods and merging multiple data sets from Abbott and the Center for Medicare Services. This study fulfills FDA conditions of approval for the Aveir DR device. The study uses data from patients already implanted with the Aveir DR Leadless Pacemaker System, without performing any new device interventions. Data collection is based on real-world evidence and involves no randomization or treatment assignment. The study utilizes a central institutional review board approved waiver of informed consent, so individual hospitals do not need to obtain patient consent or conduct local IRB submissions. The focus is on monitoring safety outcomes over time. Participants are tracked through linked Medicare data to assess complications related to the device at both 30 days and over 5 years. The study measures the number of subjects free from acute and chronic device-related complications and records end-of-device service events. The total duration of follow-up extends up to five years, using real-world data to monitor long-term device safety and performance.
Actively Recruiting
Researchers are evaluating the long-term safety and performance of the AVEIR leadless pacemaker in patients who need this device to manage heart conditions such as bradycardia, atrio-ventricular block, and syncope. This observational study is conducted within the UK National Health Service and aims to collect clinical data on patient characteristics and device outcomes in real-world settings. The study plans to recruit 600 patients across up to 15 centers over a 2-year period. The AVEIR leadless pacemaker is a device implanted without traditional leads or a pulse generator pocket. It is inserted through the femoral vein using a delivery catheter and provides cardiac pacing and sensing for bradycardia treatment. Patients will receive the device as part of their usual care, and their progress will be observed for 5 years following implantation to evaluate device-related complications, need for re-intervention, and device performance measures such as stimulation threshold and signal amplitudes. Participants will be followed according to standard clinical practice with data collected anonymously, including age, sex, medical history, and indications for pacemaker implantation. The study will monitor safety and efficacy outcomes over 5 years, with assessments focusing on complications related to the device or implantation procedure, pacing thresholds, and cardiac signal measurements. This extended follow-up period aims to provide valuable insights into the devices long-term use in routine clinical settings.
Actively Recruiting
Researchers are exploring the potential of cardioneuroablation, a minimally invasive catheter ablation technique targeting cardiac ganglionated plexi, for treating significant vagally-mediated bradycardia. This condition involves abnormally slow heart rates caused by overactive vagal nerve signals. The study combines basic science and clinical investigation to address the current lack of high-level evidence on the safety and effectiveness of this therapy, aiming to establish a reliable, evidence-based treatment strategy. This approach avoids permanent device implantation and focuses on suppressing abnormal vagal activity that contributes to bradycardia symptoms like syncope and fatigue. The study randomly assigns participants to one of two groups one receiving cardioneuroablation targeting atrial ganglionated plexi through a catheter procedure performed under local anesthesia with sedation, and the other undergoing a sham procedure without ablation or transseptal puncture. The ablation involves catheter insertion through the femoral vein, positioning in the heart guided by imaging, and sequentially ablating specific nerve clusters in the atria. The sham procedure mimics the preparation and catheter placement but does not include ablation, with participants wearing headphones and an eye mask to maintain blinding. Participants will be monitored with 24-hour ambulatory electrocardiograms at baseline and at 1, 3, 6, and 12 months post-procedure to measure average heart rate, PR interval, and heart rate variability. Quality of life will be assessed with a standardized health survey at baseline and 12 months. The study emphasizes rigorous design and standardized procedures to ensure reliable and reproducible results. Participant involvement includes multiple follow-up visits over a year to assess heart rhythm changes, symptoms, and overall wellbeing, supporting a comprehensive evaluation of the interventions impact.
Actively Recruiting
Researchers are evaluating the safety and performance of the LivIQ leadless pacemaker system in patients who require ventricular pacing for conditions like bradycardia, AV block, or other cardiac rhythm disorders. This study is an open-label, prospective, single-arm international trial enrolling 325 subjects across multiple centers in the U.S., Europe, and Asia Pacific. It includes a specific sub-study designed to assess how well the device maintains atrioventricular synchrony AVS. Participants will receive the LivIQ leadless pacemaker, which is implanted directly into the right ventricle. The study includes scheduled visits at enrollment, device implant, pre-hospital discharge, and follow-ups at 1, 3, 6, and 12 months, continuing every 6 months until regional market approval. After U.S. approval, a remote visit at 24 months will check vital status. The AVS sub-study involves additional Holter monitoring at 1 and 6 months to evaluate device performance. Participants will undergo evaluations including physical examinations, device performance assessments, and quality of life questionnaires. Researchers will monitor serious adverse device effects, pacing and sensing adequacy, battery longevity, and survival rates over time. Follow-up includes in-person visits and remote monitoring to track safety and device function, with participation lasting up to about two years or more depending on market approvals.
Actively Recruiting
Researchers are evaluating the use of BIOTRONIK dual-chamber pacemakers that combine left bundle branch area pacing LBBAP with Closed Loop Stimulation CLS in patients who have sinus node dysfunction SND and atrioventricular AV conduction disorders. This observational study aims to understand how this combined pacing method works in everyday clinical practice and whether it can help reduce atrial fibrillation detected by the device over 24 months. The goal is to gather real-world evidence to optimize pacemaker programming and improve patient outcomes. Participants receive permanent dual-chamber pacemakers with a ventricular lead placed in the left bundle branch area, activating the CLS rate-responsive algorithm. The study focuses on patients implanted with these devices who have no prior history of atrial fibrillation. The study follows about 150 patients for 24 months after implantation, collecting data on device-detected atrial fibrillation episodes, heart rate patterns, and pacing behavior. This is a prospective observational submodule of the BIOSTREAM.CSP registry without a control group. During the study, researchers monitor device-recorded atrial fibrillation incidence and burden from CLS activation up to 24 months. They also analyze heart rate histograms at one and two years after implantation. Patients are enrolled in the BIOSTREAM.CSP registry and are followed through routine clinical care with data collected on pacing rates and arrhythmia episodes. The study aims to provide insights into the clinical performance of CLS combined with LBBAP to inform decisions on pacemaker programming and reduce atrial arrhythmias.
1-10 of 80
1