Patent foramen ovale (PFO) is a small opening between the upper chambers of the heart that fails to close after birth, which can allow blood to flow abnormally between the chambers. This opening sometimes lets tiny blood clots pass from the right sid...
Search Bar & Filters
Found 24 Actively Recruiting clinical trials
Actively Recruiting
Migraine is a common chronic neurological condition linked to patent foramen ovale PFO, a frequent congenital heart defect in adults. This research investigates the connection between PFO and migraines, focusing on the effects of closing the PFO to reduce migraine symptoms. Previous studies suggest that closing the PFO with metal devices can reduce migraine days but may also cause new or worsened migraines due to permanent metal implants. The study aims to compare outcomes using a new biodegradable PFO occluder versus a traditional metal occluder. Participants will be randomly assigned to receive either the innovative MemoSorb4 biodegradable occluder, which dissolves over time to avoid complications of metal implants, or the conventional metal occluder device. The biodegradable occluder acts as a temporary bridge that gradually degrades while the heart tissue repairs itself. This single-blind, controlled trial will evaluate the safety and effectiveness of these two devices in patients with both PFO and migraine. During the study, participants will be monitored for migraine frequency and severity, with the main outcome being the reduction in migraine days per month measured at 12 months after the procedure. Follow-ups will include clinical evaluations and diagnostic testing to assess device performance and migraine relief. The total study duration and safety monitoring will span at least one year post-implantation to compare long-term effects of the two occluder types.
Actively Recruiting
Researchers are evaluating the safety and performance of Abbotts commercially available Structural Heart SH devices in real-world hospital settings. This observational registry collects data to meet regulatory requirements, such as the European Union Medical Device Regulations 2017745, by actively monitoring these devices after market approval. The study includes patients undergoing standard care procedures involving Abbott SH devices, with a focus on confirming device safety and performance across multiple device types. Participants receive one or more Abbott SH devices during routine hospital procedures, including Amplatzer Occlusion Devices for septal defects and Epic Surgical Tissue Heart Valve devices for heart valve replacement. The registry enrolls patients either before the procedure or shortly after, depending on the device type, with follow-up visits aligned with standard care schedules. Follow-up may include discharge or 7-day post-procedure visits, short-term 1-3 months, mid-term 6 months, and long-term up to 12 months or even 10 years assessments depending on the device used. A specific surgical valve sub-study collects additional data for certain valve sizes to support regulatory approval in the US. Participants are monitored through their routine care visits, which may occur in person, by phone, or virtually. Data collected include safety and effectiveness outcomes at various time points post-procedure. The registry plans to enroll approximately 500 subjects annually across about 25 global sites, with follow-up duration varying by device type to cover short- and long-term safety and performance. The total study completion is expected by November 2039, allowing extended monitoring of patient outcomes.
Actively Recruiting
Researchers are collecting real-world data on patient outcomes to assess the success and performance of the Lifetech CeraFlex PFO Closure System, a device designed to close Patent Foramen Ovale PFO without surgery. This multicenter, prospective, observational study aims to provide valuable information on how well the device works in everyday medical practice. Participants will receive the CeraFlex PFO Closure System, which includes the CeraFlex PFO Occluder and the SteerEase Introducer. The study follows patients after the procedure, tracking their progress at discharge, and then at 1-3 months, 6 months, 12 months, and 24 months post-procedure. The enrollment period is expected to last about 18 months, with each participant followed for two years after device implantation. During the study, participants will undergo various assessments including monitoring for procedural success shortly after the procedure, checking for residual shunts at several follow-up points, and tracking stroke-related events, device deficiencies, serious adverse events, and deaths up to 24 months post-implantation. Data is collected electronically to ensure accurate tracking of patient outcomes over the entire study period.
Actively Recruiting
This research aims to study cerebral microembolization in patients undergoing transcatheter closure of patent foramen ovale PFO or atrial septal defect ASD. It also investigates the link between new cerebral microembolization and in situ blood clots within the PFO. PFO is common and linked to conditions like ischemic stroke, transient ischemic attack, migraines, and embolization, with clot formation possibly playing a role in related stroke or migraine cases. Participants will receive transcatheter closure using PFO or ASD occluder devices. Before closure, brain diffusion-weighted MRI DW-MRI scans will be done, with additional DW-MRI scans at 24 hours and one month after the procedure. During PFO closure, right atrial angiography and optical coherence tomography OCT will assess the PFO structure and detect any clots while the patient performs the Valsalva maneuver. Throughout the study, patients will undergo brain imaging before and after closure to monitor cerebral microembolization and thrombus presence. Researchers will measure new cerebral microembolization occurring from 24 hours to 4 weeks after closure. The study includes detailed imaging and clot evaluations to better understand microembolization risks and outcomes following PFO or ASD closure, with participation lasting through at least one month post-procedure.
Actively Recruiting
Researchers are evaluating the safety and effectiveness of two devices used to close a patent foramen ovale PFO in adults who have experienced a cryptogenic embolic stroke or transient ischemic attack TIA within the past year. This non-profit, single-blind, randomized clinical trial compares the Cocoon PFO Occluder with the Amplatzer PFO Occluder to help identify the best option for preventing recurrent neurological events associated with PFO. Up to 1260 participants will be enrolled across multiple European centers. Participants are randomly assigned in a 31 ratio to receive either the Cocoon PFO Occluder or the Amplatzer PFO Occluder device through a percutaneous closure procedure. The procedure is performed under standard clinical practice, guided by echocardiography, and scheduled within 45 days after randomization, preferably within 14 days. After device implantation, participants follow dual antiplatelet therapy and receive recommended endocarditis prevention for six months. Both study groups undergo similar clinical and echocardiographic follow-up. During the study, participants will have routine clinical evaluations and echocardiographic imaging to assess PFO closure at 6 months and monitor for safety and device performance. The main outcome measured is a composite of recurrent ischemic stroke, TIA, or all-cause death at 12 months post-procedure. Additional assessments include neurological and cardiovascular events, adverse events, quality of life, migraine days, and device-related markers. Participation lasts up to one year with ongoing follow-up visits.
Actively Recruiting
Healthy Volunteer
This research aims to evaluate the safety of stopping antithrombotic treatment 12 months after a successful transcatheter closure of a patent foramen ovale PFO in young patients who have experienced a cryptogenic stroke or transient ischemic attack TIA. The study focuses on patients up to 60 years old and explores whether shorter-term antiplatelet therapy can reduce bleeding risks without increasing ischemic events, based on preliminary data showing bleeding risk may outweigh stroke risk during long-term follow-up. Participants will discontinue antiplatelet treatment at 12 months following their PFO closure. They will undergo clinical evaluations and cerebral MRI scans at 12 months before stopping the treatment and again at 24 months after the procedure. The study monitors the effects of stopping antiplatelet therapy and observes any new stroke or ischemic lesions over time. Throughout the study, participants will be assessed using clinical exams and brain imaging to detect new stroke events and ischemic lesions, primarily at 12 and 24 months post-PFO closure. The research team will also track the number and volume of ischemic lesions and ischemic events up to 10 years after the procedure, as well as bleeding rates. The total study duration extends up to 12 years, with ongoing safety and event monitoring to understand long-term outcomes of antithrombotic treatment discontinuation.
Actively Recruiting
Evaluating the Recross P3 Occluder Device for Closing Heart Openings in Adults Who Have Had a Stroke
Researchers are evaluating the Recross P3 Occluder System, a new heart device designed to close a small opening between the upper chambers of the heart called a Patent Foramen Ovale PFO. This trial focuses on adults aged 18 to 65 who have had a stroke that might be related to this heart opening. The main goal is to determine if the P3 Occluder System is safe and effective at closing the PFO to reduce the risk of another stroke. Participants will undergo a procedure to implant the P3 Occluder device if appropriate. After the procedure, they will have follow-up visits with their doctor at 1 month, 3 months, 6 months, 1 year, and 5 years to check their progress and device status. Additionally, study staff will contact participants by phone at 2, 3, and 4 years after the procedure to complete surveys. During the study, participants will be monitored for major heart-related events within 30 days and assessed for effective closure of the PFO at 6 months. Other safety evaluations include checking for serious device- or procedure-related events. The study also examines if the device remains correctly positioned at 6 months. Overall, participants will be involved in regular doctor visits, imaging tests, and surveys for up to 5 years to ensure thorough monitoring of their heart health and device performance.
Actively Recruiting
Patent Foramen Ovale PFO is a common heart defect that may be linked to migraines, especially migraine with aura. Researchers are studying how PFO affects the brains glymphatic system and its connection to migraine symptoms. They aim to understand if closing the PFO can improve migraines and glymphatic function, using a case-control design to compare patients with and without migraine who have PFO with significant right-to-left shunt. The study involves two groups one with PFO and migraine who receive a minimally invasive percutaneous PFO closure procedure, and a control group with PFO but no migraine who do not receive closure. The closure uses a device inserted through a catheter to seal the PFO tunnel under imaging guidance. Both groups undergo assessments of migraine symptoms and glymphatic function before and six months after intervention or enrollment. Participants will be monitored for changes in migraine frequency and pain intensity, using tools like the Monthly Migraine Days and Visual Analogue Scale for pain. Glymphatic function is measured by imaging indexes such as the DTI-ALPS. The study takes place over at least six months post-procedure or enrollment, with the goal of understanding the effects and mechanisms of PFO closure on migraine and brain function.
Actively Recruiting
Researchers are evaluating the safety, effectiveness, and noninferiority of the Encore PFO closure device compared to any FDA-approved PFO closure device chosen by investigators. The study focuses on patients who have had a cryptogenic stroke caused by a presumed paradoxical embolism and involves closing a patent foramen ovale PFO through a percutaneous, transcatheter procedure. This prospective, multicenter, randomized clinical study aims to provide reasonable assurance of the Encore devices safety and effectiveness. Participants will be randomly assigned to receive either the Encore PFO closure device, which includes an implant component and a single-use delivery system, or an FDA-approved PFO closure device selected by the investigator. The procedure involves using these devices to close the PFO via catheter-based delivery. The study design includes comparison of procedural and device-related outcomes between these two groups. During the study, participants will be monitored for safety, including the incidence of serious adverse events related to the device or procedure within 6 months. Effectiveness will be assessed by measuring the success of PFO closure at 6 months. Additional evaluations include long-term monitoring for recurrent stroke, transient ischemic attacks, new atrial arrhythmias, and procedural success over 5 years. Participants will undergo imaging, neurological assessments, and follow-up visits to track outcomes and overall safety throughout the study period.
Actively Recruiting
Researchers are establishing a headache center in China to study migraine patients who also have patent foramen ovale PFO. The study aims to explore different treatment options for this combination, identify factors that may influence outcomes, and develop models to predict prognosis. The goal is to improve understanding and care for patients with both conditions. Participants will be assigned to one of three groups based on treatment approach a conservative group that does not use antiplatelet drugs or undergo PFO closure surgery, a group that receives antiplatelet drug treatment, and a group that undergoes PFO closure surgery. The study is observational and will follow patients over time to monitor their condition. During the study, participants will be regularly monitored for changes in migraine attacks at 3 months, 6 months, 1 year, 2 years, and 3 years. The study involves clinical, imaging, and laboratory examinations to gather detailed information. Participants will be followed up to assess the effects of their treatment approach and factors influencing migraine outcomes with PFO.
1-10 of 24
1