Train-of-four monitoring with the twitchview monitor electctromyograph compared to the GE NMT electromyograph and manual palpation.
Logan Bussey, Srdjan Jelacic, Kei Togashi...
https://pubmed.ncbi.nlm.nih.gov/33165706/Actively Recruiting
Led by Ohio State University · Updated on 2026-07-15
35
Participants Needed
1
Research Sites
26 weeks
Total Duration
Researchers are comparing two electromyography EMG devices, the TetraGraph and TwitchView, to monitor deep neuromuscular blockade during elective laparoscopic, robotic, or thoracic video-assisted surgeries. The study aims to evaluate how well each device detects spontaneous diaphragmatic movements and breath-initiation efforts, which indicate the depth of muscle relaxation during surgery. This intraoperative device comparison trial uses a randomized, double-masked design to assess monitoring performance under standard anesthesia care. Participants will have both devices placed on opposite hands, with the dominant hand device guiding neuromuscular blockade management. The devices measure muscle responses using Train-of-Four and post-tetanic count methods continuously during surgery. Standard anesthesia protocols, including rocuronium administration and sugammadex reversal, are maintained. Data collected include device outputs, neuromuscular blocking agent dosing, physiological parameters, and clinical observations. After surgery, providers will complete surveys to assess device usability and workflow integration. Participants undergo assessments during surgery, including neuromuscular function monitoring at various time points from baseline through emergence from anesthesia. Researchers will track diaphragmatic movements, breath efforts, intubation difficulty, vocal cord visibility and movement, recovery times, and usability scores. All data are gathered without altering standard patient care. The study runs from February 2026 to August 2028, with participant involvement limited to the surgery and immediate postoperative period.
CONDITIONS
Comparison of Two Quantitative EMG Monitors for Deep Neuromuscular Block in Laparoscopic/Robotic and VATS Surgery
A
Alberto Uribe, MD
E
Elvia Vera, MD
Explore thousands of other clinical trials that might be a better match.
Sign up to get personalized trial recommendations delivered to your inbox.
Already have an account? Log in here
Ohio State University
Lead Sponsor
This table compares participation in this trial with other options available for this condition. The information is drawn from published research and the trial’s study details and is provided for educational purposes only.
| Factors | TetraGraph (Senzime) EMG (Dominant Hand) | TwitchView (Blink) EMG (Dominant Hand) |
|---|---|---|
| What it is | A quantitative electromyography (EMG) neuromuscular monitor applied to the dominant hand, used continuously during surgery to guide deep neuromuscular blockade and support recovery through train-of-four and post-tetanic count monitoring. | A quantitative EMG neuromuscular monitor applied to the dominant hand, similarly used to monitor deep muscle relaxation and recovery during major surgery, collecting train-of-four and post-tetanic count measurements at protocol-defined intervals. |
| Role in the trial | Assigned as the neuromuscular monitoring device in one randomized arm, guiding dosing of muscle relaxants (rocuronium) and timing of reversal and extubation. | Assigned as the monitoring device in the other randomized arm, fulfilling the same purpose for rocuronium redosing, monitoring deep blockade, and timing reversal and extubation based on EMG data. |
| Primary use | To provide continuous and objective EMG-based assessment of neuromuscular blockade depth, enabling maintenance of deep blockade and safe reversal before extubation. | Similarly, to monitor and guide deep neuromuscular blockade using quantitative EMG signals, supporting clinical dosing and extubation timing decisions. |
| How it is given or performed | Surface electrodes are placed on the dominant hand’s ulnar nerve after anesthesia induction. The device is calibrated, then measures train-of-four approximately every 15 seconds and post-tetanic count every 5 minutes (when indicated), with dosing and reversal decisions broadcast from device readings. | After anesthesia starts, the TwitchView device is applied to the dominant hand, electrodes placed per protocol, and baseline train-of-four obtained. It records train-of-four every 15 seconds, post-tetanic count every 5 minutes when TOF is zero, guiding rocuronium dosing and timing of reversal/extubation based on EMG data. |
| Evidence status | Efficacy and performance for intraoperative monitoring are under direct investigation in this randomized clinical trial; prior published literature on TetraGraph is limited for deep blockade in this specific surgery type. | Efficacy and reliability in intraoperative neuromuscular monitoring have been evaluated in prior studies. Published data suggest valid train-of-four monitoring and good agreement with other quantitative EMG devices in surgical settings, with ongoing investigation of comparative performance. |
| Important limitations | Potential limitations include limited published experience in this procedure type and device accuracy under extreme neuromuscular blockade states; as with all surface EMG monitors, performance may be affected by patient anatomy, electrode placement, or signal noise. | Limitations may include dependency on proper electrode application and signal quality; false readings or device malfunctions have been reported for train-of-four monitoring, and results may vary with extreme neuromuscular blockade and positioning. User experience and device usability are further evaluated in this trial. |
Disclaimer: This comparison is created with the help of artificial intelligence(AI) and may contain errors or missing information. It is not medical advice and does not mean one option is better or safer than another. Clinical trials are still being studied, and joining a trial is your choice. Please consult your healthcare professional before making any decisions.
You may qualify if you...
You will not qualify if you...
Duration - 2 to 4 weeks
Participants are screened for eligibility to participate in the trial.
1 visit (in-person)
Duration - Duration of surgery (more than 3 hours)
Participants undergo elective laparoscopic, robotic, or thoracic video-assisted surgery under general anesthesia. Two electromyography devices are placed on opposite hands to monitor neuromuscular blockade continuously during the procedure. The dominant hand device guides management of muscle relaxation. Standard anesthesia care is maintained throughout.
Continuous monitoring during surgery
Duration - Immediately after surgery
After surgery, providers complete surveys to assess device usability, signal quality, and overall satisfaction. Data on neuromuscular function and recovery are collected from device outputs and clinical records.
1 survey completion
Study Type
INTERVENTIONAL
Masking
DOUBLE
Allocation
RANDOMIZED
Model
PARALLEL
Primary Purpose
DIAGNOSTIC
Number of Arms
2
Have more questions? Get in touch with our team for quick support
Logan Bussey, Srdjan Jelacic, Kei Togashi...
https://pubmed.ncbi.nlm.nih.gov/33165706/Aaron F Kopman, Sorin J Brull
https://pubmed.ncbi.nlm.nih.gov/40193198/K Matsuda
https://pubmed.ncbi.nlm.nih.gov/792367/Manfred Blobner, Christiane G Frick, Roland B Stäuble...
https://pubmed.ncbi.nlm.nih.gov/25125097/J S Ahluwalia, C J Morley, J N Mockridge
https://pubmed.ncbi.nlm.nih.gov/7820709/Ohio State University
Lead Sponsor